APLISENS SA Warszawa, Poland
emergency power suppliesflow meters, fuel oillevelpressure, vacuumtransducers, transmitters temperature and pressurevalve, pressure controlvalve, pressure reducing
APC-2000 ALWAPCE-2000PD and APCE-2000PZAPR-2000 ALWAPR-2000G ALAPRE-2000GAPRE-2000PD and APRE-2000PZAPRE-2200ASAS-dPCS-25/I; CS-25/U; CS-25/RSMS-100K PCE-28PCE-28PPRE-28SG.Profibus PASGE-25 Smart and SGE-25S SmartSGE-25 and SGE-16SGE-25S and SGE-25CVM-3 and VM-5ZL-24-01ZL-24-08ZS-30EEx1ZS-31EEx1ZSP-41
Presentation: www.aplisens.equip4ship.com
Address: Poland, Warszawa, 03-192 Morelowa 7
Contact person: e-mail, website
Smart differential pressure transmitter
Send enquiry
Measuring range: min. 0...4 mbar, max. 0...16 bar
Output signal: 4...20 mA, 0...20 mA or 0...5 mA + protocol HART; Profibus PA
Accuracy: 0,075%
Output signal: 4...20 mA, 0...20 mA or 0...5 mA + protocol HART; Profibus PA
Accuracy: 0,075%
APR-2000 ALW
Smart differential pressure transmitter
Send enquiry
Measuring range: min. 0 ... 4 mbar, max. 0... 16 bar
Output signal: 4...20 mA + protocol HART
Accuracy: 0,1%
Output signal: 4...20 mA + protocol HART
Accuracy: 0,1%
APRE-2000PD and APRE-2000PZ
Differential pressure transmitter
Send enquiry
Measuring range: min. 0 ... 20 mbar, max. 0... 16 bar
Output signal: 4...20 mA, 0...10 V
Accuracy: 0,25%
Output signal: 4...20 mA, 0...10 V
Accuracy: 0,25%
PRE-28
Differential pressure transmitter
Send enquiry
Measuring range: min. 0 ... 1 bar, max. 0... 25 bar
Output signal: 4...20 mA, 0...10 V
Accuracy: 0,4%
Output signal: 4...20 mA, 0...10 V
Accuracy: 0,4%
AS-dP
Smart differential pressure transmitter for low ranges
Send enquiry
Programmable zero shift and damping ratio
Selectable linear or radical conversion characteristic
Output signal: 4...20 mA + HART
Accuracy: 0,1% (1%)
Selectable linear or radical conversion characteristic
Output signal: 4...20 mA + HART
Accuracy: 0,1% (1%)
APR-2000G AL
Smart pressure transmitter for low ranges
Send enquiry
Measuring range: min. 0 ... 0,2 mbar, max. 0... 100 mbar
Output signal: 4...20 mA + HART
Accuracy: 0,1% (1%)
Process connection: to fi 6x1 pipe, mounted with a valve manifold
Output signal: 4...20 mA + HART
Accuracy: 0,1% (1%)
Process connection: to fi 6x1 pipe, mounted with a valve manifold
APRE-2000G
Level measurement
Send enquiry
Smart or analog differential pressure transmitters with diaphragm seals for level measurement
Smart differential pressure transmitter with remote diaphragm seals
Send enquiry
Measuring range: min. 0 ... 0,1mH2O, max. 0... 16 bar
Output signal: 4...20 mA + protocol HART; Profibus PA
Accuracy: 0,1%
Output signal: 4...20 mA + protocol HART; Profibus PA
Accuracy: 0,1%
APRE-2200
Smart pressure transmitter
Send enquiry
Measuring range: min. 0...1 mbar; max. 0... 400 bar
Output signal: 4...20 mA, 0...20 mA or 0...5 mA + protocol HART; Profibus PA
Accuracy: 0,075%
Process connection: M20 x 1,5; G 1/2"; G 1/2";
G 1" (flush diaphragm); M30 x 2;
M20 x 1,5
Output signal: 4...20 mA, 0...20 mA or 0...5 mA + protocol HART; Profibus PA
Accuracy: 0,075%
Process connection: M20 x 1,5; G 1/2"; G 1/2";
G 1" (flush diaphragm); M30 x 2;
M20 x 1,5
APC-2000 ALW
Smart pressure transmitter
Send enquiry
Measuring range: min. 0...1 mbar; max. 0...400 bar
Output signal: 4...20 mA + protocol HART
Accuracy: 0,1% (0,075%)
Process connection: M20 x 1,5; G 1/2"; G 1/2";
G 1" (flush diaphragm); M30 x 2;
M20 x 1,5;
Diaphragm seals;
Output signal: 4...20 mA + protocol HART
Accuracy: 0,1% (0,075%)
Process connection: M20 x 1,5; G 1/2"; G 1/2";
G 1" (flush diaphragm); M30 x 2;
M20 x 1,5;
Diaphragm seals;
APCE-2000PD and APCE-2000PZ
Pressure transmitter
Send enquiry
Measuring range: min. 0...10 mbar; max. 0...1000 bar
Output signal: 4...20 mA, 0...10 V
Accuracy: 0,2% (0,16%)
Process connection: M20 x 1,5; G 1"; G 1/2";
G 1" (flush diaphragm); M30 x 2;
M20 x 1,5;
Diaphragm seals
Output signal: 4...20 mA, 0...10 V
Accuracy: 0,2% (0,16%)
Process connection: M20 x 1,5; G 1"; G 1/2";
G 1" (flush diaphragm); M30 x 2;
M20 x 1,5;
Diaphragm seals
PCE-28
Pressure transmitter
Send enquiry
Measuring range: min. 0 ... 0,1 bar; max. 0... 60 bar
Output signal: 4...20 mA, 0...10 V
Accuracy: 0,4%
Process connection: M20 x1,5; G 1/2"; R 1/2"
Output signal: 4...20 mA, 0...10 V
Accuracy: 0,4%
Process connection: M20 x1,5; G 1/2"; R 1/2"
AS
Gauge model (also with diaphragm seal)
Send enquiry
Measuring range: min. 0 ... 1 bar; max. 0... 400 bar
Casing diameter 100 mm
Accuracy: 1%
Process connection: M20 x1,5
Casing diameter 100 mm
Accuracy: 1%
Process connection: M20 x1,5
MS-100K
3-way and 5-way valve manifolds
Send enquiry
Hydrostatic level probes
Send enquiry
Measuring range: min. 0...1 m W.C, max. 0...500 m W.C.;
Output signal: 4...20 mA, 0...10 V, 0...2,5 V (and other);
Accuracy: 0,2%
Output signal: 4...20 mA, 0...10 V, 0...2,5 V (and other);
Accuracy: 0,2%
SGE-25 and SGE-16
Hydrostatic level probe
Send enquiry
Measuring range: min. 0...2 m W.C., max. 0...20 m W.C.
Output signal: 4...20 mA, 0...10 V
Accuracy: 0,5%
Output signal: 4...20 mA, 0...10 V
Accuracy: 0,5%
SGE-25S and SGE-25C
Smart hydrostatic level probes
Send enquiry
Measuring range: min. 0...0,8 m W.C., max. 0...115 m W.C.
Output signal: 4...20 mA + HART protocol;
Accuracy: 0,1%
Output signal: 4...20 mA + HART protocol;
Accuracy: 0,1%
SGE-25 Smart and SGE-25S Smart
Hydrostatic level probe
Send enquiry
Measuring range: min. 0...200 mm W.C., max. 0...3000 mm W.C.
Output signal: 4...20 mA, 0...10 V, (0...20 mA)
Accuracy: 0,5%
Output signal: 4...20 mA, 0...10 V, (0...20 mA)
Accuracy: 0,5%
PCE-28P
Smart hydrostatic level probe
Send enquiry
Measuring range: min. 0...0,8 m W.C., max. 0...115 m W.C.
Output signal: Profibus PA
Accuracy: 0,1%
Output signal: Profibus PA
Accuracy: 0,1%
SG.Profibus PA
Fuel Level Probe
Send enquiry
Measuring range 0รท800 mm H2O
Ministry of Transport Type Approval
Ministry of Transport Type Approval
CS-25/I; CS-25/U; CS-25/RS
Intrinsically safe network power supply and separator
Send enquiry
230 V AC power supply
Full galvanic separation of circuits (IN-OUT, IN-SUPPLY, OUT-SUPPLY)
Accuracy 0.1%
Casing can be fitted on a standard TS35 rail
Full galvanic separation of circuits (IN-OUT, IN-SUPPLY, OUT-SUPPLY)
Accuracy 0.1%
Casing can be fitted on a standard TS35 rail
ZS-31EEx1
Intrinsically safe power supply and separator
Send enquiry
24 V DC power supply
Full galvanic separation of circuits (IN-OUT, IN-SUPPLY, OUT-SUPPLY)
Accuracy 0.1%
Casing can be fitted on a standard TS35 rail
Full galvanic separation of circuits (IN-OUT, IN-SUPPLY, OUT-SUPPLY)
Accuracy 0.1%
Casing can be fitted on a standard TS35 rail
ZS-30EEx1
Power supply/separator/signal converter
Send enquiry
Full galvanic separation of circuits (IN-OUT, IN-SUP, OUT-SUP)
Ability to select input and output signals
Ability to use input line to power a two-wire transmitter
Casing can be fitted on a standard TS35 rail
Ability to select input and output signals
Ability to use input line to power a two-wire transmitter
Casing can be fitted on a standard TS35 rail
ZSP-41
Power supply
Send enquiry
Maximum output current 100 mA or 2 x 50 mA
Indication of presence of output voltage
Permanently resistant to short circuits and excess voltage
Casing can be fitted on a standard TS35 rail
Indication of presence of output voltage
Permanently resistant to short circuits and excess voltage
Casing can be fitted on a standard TS35 rail
ZL-24-01
Power supply
Send enquiry
Maximum output current 800 mA
High energy efficiency
Indication of the presence of output voltage
Permanently resistant to short circuiting and excess voltage
Overvoltage protection
Casing can be fitted on a standard TS35 rail
High energy efficiency
Indication of the presence of output voltage
Permanently resistant to short circuiting and excess voltage
Overvoltage protection
Casing can be fitted on a standard TS35 rail
ZL-24-08